Aerospace Testing Facilities available in India
![]() |
||
| Title of the Aerospace Test |
Environmental Testing & Calibration |
|
| Name of the Organisation |
ECIL |
|
| Name of theLab |
Environmental Testing & Calibration Laboratories - ETCL |
|
| Place of the Lab |
Hyderabad |
|
| Category of Aerospace Test | Environmental Testing | |
| Sub-category of Aerospace Test | NA | |
| Year of Establisment | 1967 | |
| Test Applications | Vibrartion Test upto 83 g peak Low Temperatute Test upto -60 degree Celsius High Temperature Test upto +150 degree Celsius Damp Heat Test upto +60 degree Celsius, 95% RH Altitude Test upto 20 milli ber Environmental Stress Screening Ramp Rate 5 degree Celsius / min |
|
| Test Special Features | QVibrartion Test can be performed in X, Yand Z-axis |
|
| Other Test Information | Frequency Range 5 Hz to 2800 Hz, Displacement 51 mm p-p Added Environmental Stress Screening Facility, Vibrartion Test System. Compliance to MIL-STD-810F, JSS 55555 Standards |
|
| Contact Person / Institution | The Director Electronics Corporation of India Limited (ECIL) PO. ECIL, Hyderabad - 500 062. ECIL Board : +91-40-27120131(10 lines) Email : cbdg@ecil.co.in Website:http://www.ecil.co.in/home.html |
|