Aerospace Testing Facilities available in India
|
||
Title of the Aerospace Test |
Environmental Testing & Calibration |
|
Name of the Organisation |
ECIL |
|
Name of theLab |
Environmental Testing & Calibration Laboratories - ETCL |
|
Place of the Lab |
Hyderabad |
|
Category of Aerospace Test | Environmental Testing | |
Sub-category of Aerospace Test | NA | |
Year of Establisment | 1967 | |
Test Applications | Vibrartion Test upto 83 g peak Low Temperatute Test upto -60 degree Celsius High Temperature Test upto +150 degree Celsius Damp Heat Test upto +60 degree Celsius, 95% RH Altitude Test upto 20 milli ber Environmental Stress Screening Ramp Rate 5 degree Celsius / min |
|
Test Special Features | QVibrartion Test can be performed in X, Yand Z-axis |
|
Other Test Information | Frequency Range 5 Hz to 2800 Hz, Displacement 51 mm p-p Added Environmental Stress Screening Facility, Vibrartion Test System. Compliance to MIL-STD-810F, JSS 55555 Standards |
|
Contact Person / Institution | The Director Electronics Corporation of India Limited (ECIL) PO. ECIL, Hyderabad - 500 062. ECIL Board : +91-40-27120131(10 lines) Email : cbdg@ecil.co.in Website:http://www.ecil.co.in/home.html |
|